Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 16 de 16
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Clin Transl Radiat Oncol ; 46: 100760, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38510980

RESUMO

Purpose: MR-guided radiotherapy (MRgRT) has the advantage of utilizing high soft tissue contrast imaging to track daily changes in target and critical organs throughout the entire radiation treatment course. Head and neck (HN) stereotactic body radiation therapy (SBRT) has been increasingly used to treat localized lesions within a shorter timeframe. The purpose of this study is to examine the dosimetric difference between the step-and-shot intensity modulated radiation therapy (IMRT) plans on Elekta Unity and our clinical volumetric modulated arc therapy (VMAT) plans on Varian TrueBeam for HN SBRT. Method: Fourteen patients treated on TrueBeam sTx with VMAT treatment plans were re-planned in the Monaco treatment planning system for Elekta Unity MR-Linac (MRL). The plan qualities, including target coverage, conformity, homogeneity, nearby critical organ doses, gradient index and low dose bath volume, were compared between VMAT and Monaco IMRT plans. Additionally, we evaluated the Unity adaptive plans of adapt-to-position (ATP) and adapt-to-shape (ATS) workflows using simulated setup errors for five patients and assessed the outcomes of our treated patients. Results: Monaco IMRT plans achieved comparable results to VMAT plans in terms of target coverage, uniformity and homogeneity, with slightly higher target maximum and mean doses. The critical organ doses in Monaco IMRT plans all met clinical goals; however, the mean doses and low dose bath volumes were higher than in VMAT plans. The adaptive plans demonstrated that the ATP workflow may result in degraded target coverage and OAR doses for HN SBRT, while the ATS workflow can maintain the plan quality. Conclusion: The use of Monaco treatment planning and online adaptation can achieve dosimetric results comparable to VMAT plans, with the additional benefits of real-time tracking of target volume and nearby critical structures. This offers the potential to treat aggressive and variable tumors in HN SBRT and improve local control and treatment toxicity.

2.
Phys Imaging Radiat Oncol ; 29: 100524, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-38192414

RESUMO

While current MR-Linac (MRL) treatment workflows utilize a large table overlay during CT simulation to convert indexing between the two machines, we developed a look-up-table (LUT) as an alternative approach. After populating the LUT, index conversion factors were verified at three separate table locations. The resultant root-mean-square isocenter shifts on the MRL were 0.04/0.08 cm, 0.08/0.07 cm, and 0.09/0.08 cm with/without using the table overlay during simulation in the lateral, longitudinal, and vertical directions, respectively, which is within registration tolerance. Clinical implementation of the LUT has resulted in a more efficient MRL treatment workflow while maintaining accurate patient setup.

3.
Med Phys ; 50(11): 6639-6648, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37706560

RESUMO

BACKGROUND: In recent years, deep-learning models have been used to predict entire three-dimensional dose distributions. However, the usability of dose predictions to improve plan quality should be further investigated. PURPOSE: To develop a deep-learning model to predict high-quality dose distributions for volumetric modulated arc therapy (VMAT) plans for patients with gynecologic cancer and to evaluate their usability in driving plan quality improvements. METHODS: A total of 79 VMAT plans for the female pelvis were used to train (47 plans), validate (16 plans), and test (16 plans) 3D dense dilated U-Net models to predict 3D dose distributions. The models received the normalized CT scan, dose prescription, and target and normal tissue contours as inputs. Three models were used to predict the dose distributions for plans in the test set. A radiation oncologist specializing in the treatment of gynecologic cancers scored the test set predictions using a 5-point scale (5, acceptable as-is; 4, prefer minor edits; 3, minor edits needed; 2, major edits needed; and 1, unacceptable). The clinical plans for which the dose predictions indicated that improvements could be made were reoptimized with constraints extracted from the predictions. RESULTS: The predicted dose distributions in the test set were of comparable quality to the clinical plans. The mean voxel-wise dose difference was -0.14 ± 0.46 Gy. The percentage dose differences in the predicted target metrics of D 1 % ${D}_{1{\mathrm{\% }}}$ and D 98 % ${D}_{98{\mathrm{\% }}}$ were -1.05% ± 0.59% and 0.21% ± 0.28%, respectively. The dose differences in the predicted organ at risk mean and maximum doses were -0.30 ± 1.66 Gy and -0.42 ± 2.07 Gy, respectively. A radiation oncologist deemed all of the predicted dose distributions clinically acceptable; 12 received a score of 5, and four received a score of 4. Replanning of flagged plans (five plans) showed that the original plans could be further optimized to give dose distributions close to the predicted dose distributions. CONCLUSIONS: Deep-learning dose prediction can be used to predict high-quality and clinically acceptable dose distributions for VMAT female pelvis plans, which can then be used to identify plans that can be improved with additional optimization.


Assuntos
Aprendizado Profundo , Neoplasias , Radioterapia de Intensidade Modulada , Humanos , Feminino , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Órgãos em Risco
4.
Clin Transl Radiat Oncol ; 43: 100674, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37753462

RESUMO

We compiled a sampling of the treatment techniques of intensity-modulated total body irradiation, total marrow irradiation and total marrow and lymphoid irradiation utilized by several centers across North America and Europe. This manuscript does not serve as a consensus guideline, but rather is meant to serve as a convenient reference for centers that are considering starting an intensity-modulated program.

5.
Head Neck ; 45(10): 2525-2532, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37534890

RESUMO

BACKGROUND: There are limited studies and no surveillance protocols on pituitary dysfunction for adults who underwent anterior skull base radiation. METHODS: Cross-sectional study of 50 consecutive patients with sinonasal or nasopharyngeal cancer who underwent definitive radiotherapy. The mean radiation doses, prevalence of pituitary dysfunction, and associated factors were calculated. RESULTS: Pituitary hormone levels were abnormal in 23 (46%) patients, including 6 (12%) with symptomatic abnormalities requiring treatment. The most common hormonal abnormality was hyperprolactinemia (30%), central hypothyroidism (8%) and central hypogonadism (6%). Patients with abnormal pituitary hormone values received higher mean radiation doses to the pituitary gland (1143 cGy, P = 0.04), pituitary stalk (1129 cGy, P = 0.02), optic chiasm (1094 cGy, P = 0.01), and hypothalamus (900 cGy, P = 0.01). CONCLUSIONS: Nearly half of the patients had abnormal pituitary function, including over a tenth requiring treatment. There may be a dose-dependent association between hormonal dysfunction and radiation.


Assuntos
Neoplasias Nasofaríngeas , Adulto , Humanos , Neoplasias Nasofaríngeas/radioterapia , Prevalência , Estudos Transversais , Hipófise , Hormônios Hipofisários , Carcinoma Nasofaríngeo/radioterapia
6.
medRxiv ; 2023 May 05.
Artigo em Inglês | MEDLINE | ID: mdl-37205359

RESUMO

Objectives: We aim to characterize the serial quantitative apparent diffusion coefficient (ADC) changes of the target disease volume using diffusion-weighted imaging (DWI) acquired weekly during radiation therapy (RT) on a 1.5T MR-Linac and correlate these changes with tumor response and oncologic outcomes for head and neck squamous cell carcinoma (HNSCC) patients as part of a programmatic R-IDEAL biomarker characterization effort. Methods: Thirty patients with pathologically confirmed HNSCC who received curative-intent RT at the University of Texas MD Anderson Cancer Center, were included in this prospective study. Baseline and weekly Magnetic resonance imaging (MRI) (weeks 1-6) were obtained, and various ADC parameters (mean, 5 th , 10 th , 20 th , 30 th , 40 th , 50 th , 60 th , 70 th , 80 th , 90 th and 95 th percentile) were extracted from the target regions of interest (ROIs). Baseline and weekly ADC parameters were correlated with response during RT, loco-regional control, and the development of recurrence using the Mann-Whitney U test. The Wilcoxon signed-rank test was used to compare the weekly ADC versus baseline values. Weekly volumetric changes (Δvolume) for each ROI were correlated with ΔADC using Spearman's Rho test. Recursive partitioning analysis (RPA) was performed to identify the optimal ΔADC threshold associated with different oncologic outcomes. Results: There was an overall significant rise in all ADC parameters during different time points of RT compared to baseline values for both gross primary disease volume (GTV-P) and gross nodal disease volumes (GTV-N). The increased ADC values for GTV-P were statistically significant only for primary tumors achieving complete remission (CR) during RT. RPA identified GTV-P ΔADC 5 th percentile >13% at the 3 rd week of RT as the most significant parameter associated with CR for primary tumor during RT (p <0.001). Baseline ADC parameters for GTV-P and GTV-N didn't significantly correlate with response to RT or other oncologic outcomes. There was a significant decrease in residual volume of both GTV-P & GTV-N throughout the course of RT. Additionally, a significant negative correlation between mean ΔADC and Δvolume for GTV-P at the 3 rd and 4 th week of RT was detected (r = -0.39, p = 0.044 & r = -0.45, p = 0.019, respectively). Conclusion: Assessment of ADC kinetics at regular intervals throughout RT seems to be correlated with RT response. Further studies with larger cohorts and multi-institutional data are needed for validation of ΔADC as a model for prediction of response to RT.

7.
Pract Radiat Oncol ; 13(3): e282-e291, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36697347

RESUMO

PURPOSE: This study aimed to use deep learning-based dose prediction to assess head and neck (HN) plan quality and identify suboptimal plans. METHODS AND MATERIALS: A total of 245 volumetric modulated arc therapy HN plans were created using RapidPlan knowledge-based planning (KBP). A subset of 112 high-quality plans was selected under the supervision of an HN radiation oncologist. We trained a 3D Dense Dilated U-Net architecture to predict 3-dimensional dose distributions using 3-fold cross-validation on 90 plans. Model inputs included computed tomography images, target prescriptions, and contours for targets and organs at risk (OARs). The model's performance was assessed on the remaining 22 test plans. We then tested the application of the dose prediction model for automated review of plan quality. Dose distributions were predicted on 14 clinical plans. The predicted versus clinical OAR dose metrics were compared to flag OARs with suboptimal normal tissue sparing using a 2 Gy dose difference or 3% dose-volume threshold. OAR flags were compared with manual flags by 3 HN radiation oncologists. RESULTS: The predicted dose distributions were of comparable quality to the KBP plans. The differences between the predicted and KBP-planned D1%,D95%, and D99% across the targets were within -2.53% ± 1.34%, -0.42% ± 1.27%, and -0.12% ± 1.97%, respectively, and the OAR mean and maximum doses were within -0.33 ± 1.40 Gy and -0.96 ± 2.08 Gy, respectively. For the plan quality assessment study, radiation oncologists flagged 47 OARs for possible plan improvement. There was high interphysician variability; 83% of physician-flagged OARs were flagged by only one of 3 physicians. The comparative dose prediction model flagged 63 OARs, including 30 of 47 physician-flagged OARs. CONCLUSIONS: Deep learning can predict high-quality dose distributions, which can be used as comparative dose distributions for automated, individualized assessment of HN plan quality.


Assuntos
Aprendizado Profundo , Radioterapia de Intensidade Modulada , Humanos , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Órgãos em Risco , Radioterapia de Intensidade Modulada/métodos
8.
J Appl Clin Med Phys ; 22(4): 151-157, 2021 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-33733608

RESUMO

The Xstrahl 300 orthovoltage unit is designed to deliver kilovoltage radiation therapy using the appositional technique. However, it is not equipped with some typical linear accelerator features, such as mechanical distance indicator and crosshair projection, which are useful for facilitating equipment setup during various quality assurance (QA) and research activities. Therefore, we designed and constructed slip-in devices to facilitate QA for dosimetric measurements of our Xstrahl 300 unit. These include: (a) an ion chamber positioning system for dosimetric measurements, (b) a mechanical pointer for setting dosimeter distance to a nominal 50 cm, and (c) a crosshair projector with built-in light to facilitate alignment of dosimeter to the center of the radiation field. These devices provide a high degree of setup reproducibility thereby minimizing setup errors. We used these devices to perform QA of the Xstrahl 300 orthovoltage unit. One of the QA tests we perform is a constancy check of beam output and energy. Our data since start of clinical use of this unit (approximately 2.5 yr) show dose outputs to be remarkably reproducible (2σ = ±0.4%) for all three clinical beams (75, 125, and 250 kVp). These devices have provided both convenience and high-precision during the unit's commissioning, and continue to provide the same for various QA activities on the Xstrahl 300 orthovoltage unit.


Assuntos
Garantia da Qualidade dos Cuidados de Saúde , Radiometria , Humanos , Aceleradores de Partículas , Dosímetros de Radiação , Reprodutibilidade dos Testes
9.
Clin Transl Radiat Oncol ; 24: 79-82, 2020 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-32642563

RESUMO

We hypothesized that deep inspiration breath-hold (DIBH) and computed-tomography image-guided radiotherapy (CT-IGRT) may be beneficial to decrease dose to organs at risk (OARs), when treating the stomach with radiotherapy for lymphoma. We compared dosimetric parameters of OARs from plans generated using free-breathing (FB) versus DIBH for 10 patients with non-Hodgkin lymphoma involving the stomach treated with involved site radiotherapy. All patients had 4DCT and DIBH scans. Planning was performed with intensity modulated radiotherapy (IMRT) to 30.6 Gy in 17 fractions. Differences in target volume and dosimetric parameters were assessed using a paired two-sided t-test. All heart and left ventricle parameters including mean dose, V30, V20, V10, and V5 were statistically significantly lower with DIBH. For IMRT-FB plans the average mean heart dose was 4.9 Gy compared to 2.6 Gy for the IMRT-DIBH group (p < 0.001). There was a statistically significant decrease in right kidney dose with DIBH. For lymphoma patients treated to the stomach with IMRT, DIBH provides superior OAR sparing compared to FB-based planning, most notably reducing dose to the heart and left ventricle. This strategy could be considered when treating other gastric malignancies.

10.
J Appl Clin Med Phys ; 20(4): 106-114, 2019 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-30889312

RESUMO

PURPOSE: To characterize the stacked and staggered dual-layer multileaf collimator (MLC) on the HalcyonTM system. METHODS: The novel MLC assembly was reviewed and compared to the widely used MillenniumTM 120-leaf MLC system. We investigated the MLC positioning stability over 70 days using Machine Performance Check (MPC) data. We evaluated the leaf transmission, penumbra, leaf end effect, and leaf edge effect. Leaf transmission through distal, proximal, and both MLC layers was measured with a Farmer chamber, by comparing an open and a closed field. Leaf penumbra was measured using film for three different MLC-defined field sizes. The leaf end effect was measured with sweeping gap fields of varying gap sizes defined by the distal MLC. The leaf edge effect was evaluated using the Electronic Portal Imaging Device (EPID) for the different banks, gantry positions, and collimator angles. Point dose measurements for 10 test plans were compared to dose predictions of two dose calculation model versions. RESULTS: From MPC data, the largest measured MLC positioning accuracy deviation was within 0.1 mm. The proximal MLC exhibited greater deviations compared to the distal MLC. The distal-and-proximal-combination had reduced inter-leaf and intra-leaf transmission compared to delivery with distal-only. The measured leaf transmission was 0.41% for distal-only, 0.40% for proximal-only, and negligible for distal-and-proximal-combination. The leaf end penumbra was wider compared to the leaf edge penumbra. The leaf end effect was measured to be -0.2 mm. The leaf edge effect showed minimal bank, gantry position, and collimator angle dependence. However, a systematic deviation between measurements and treatment planning system handling of the leaf edge effect was observed. The discrepancy between the measured and predicted dose in the 10 test plans improved with the latest version of the dose calculation algorithm. CONCLUSION: The characteristics of the stacked and staggered dual-layer MLC on the HalcyonTM system were presented.


Assuntos
Algoritmos , Neoplasias/radioterapia , Aceleradores de Partículas/instrumentação , Imagens de Fantasmas , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/instrumentação , Humanos , Órgãos em Risco/efeitos da radiação , Radiometria , Dosagem Radioterapêutica , Radioterapia de Intensidade Modulada/métodos
11.
Int J Radiat Oncol Biol Phys ; 103(5): 1251-1260, 2019 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-30508619

RESUMO

PURPOSE: Geometric indicators of contouring accuracy suffer from lack of clinical context in radiation therapy. To provide clinical relevance, treatment plans should be generated from the candidate contours, but manual planning could introduce confounding variations. Therefore, our objectives in this study were as follows: (1) determine the feasibility of using automated knowledge-based planning as an objective tool to generate dosimetric parameters for contour evaluation, (2) evaluate the correlation between geometric indices and dosimetric endpoints, and (3) report the dosimetric impact of multiple observations of head and neck target and organ-at-risk (OAR) volumes contoured by resident physicians. METHODS AND MATERIALS: Twenty-two resident physicians contoured the clinical target volumes, parotids, and cochleae for a nasopharyngeal cancer case, and expert-generated contours were defined as the gold standard for this study. A validated knowledge-based planning routine generated 67 treatment plans with various resident/gold-standard and target/OAR combinations. Dosimetric indices (dose to hottest 98% volume of planning target volume, and mean dose of OAR) were calculated on gold-standard contours. Commonly used geometric indices (Dice coefficients, Hausdorff maximum/mean/median distances, volume differences, and centroid distances) were also calculated. R2 quantified the correlation between geometric and dosimetric indices. RESULTS: The correlation between geometric and dosimetric indices was weak (R2 < 0.2 for 61% of the correlations studied-77 of 126) and inconsistent (no single geometric index consistently exhibited superior/inferior correlation with dosimetric endpoints). The lack of consistent correlations between geometric and dosimetric indices resulted in the inability to define any geometric index thresholds for clinical acceptability. Geometric indices also exhibited a high propensity for false positives and false negatives as a classifier of dosimetric impact. Finally, we found substantial interresident contour variation, whether quantified using geometric or dosimetric indices, with significant negative dosimetric impact should these contours be used clinically. CONCLUSIONS: Contour variation among resident physicians significantly affected dosimetric endpoints, highlighting the importance of resident education in head and neck anatomy delineation. Whenever available, dosimetric indices generated from automated planning should be used alongside geometric indices in radiation therapy contouring studies.


Assuntos
Internato e Residência , Neoplasias Nasofaríngeas/diagnóstico por imagem , Órgãos em Risco/diagnóstico por imagem , Radioterapia (Especialidade) , Cóclea/diagnóstico por imagem , Reações Falso-Negativas , Reações Falso-Positivas , Estudos de Viabilidade , Humanos , Neoplasias Nasofaríngeas/patologia , Glândula Parótida/diagnóstico por imagem , Estudos Prospectivos , Dosagem Radioterapêutica , Padrões de Referência , Tomografia Computadorizada por Raios X
12.
J Appl Clin Med Phys ; 19(4): 98-102, 2018 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29785729

RESUMO

Halcyon™ is a single-energy (6 MV-FFF), bore-enclosed linear accelerator. Patient setup is performed by first aligning to external lasers mounted to the front of the bore, and then loading to isocenter through pre-defined couch shifts. There is no light field, optical distance indicator or front pointer mechanism, so positioning is verified through MV imaging with kV imaging scheduled to become available in the future. TG-51 reference dosimetry was successfully performed for Halcyon™ in this imaging-based setup paradigm. The beam quality conversion factor, kQ , was determined by measuring %dd(10)x three ways: (a) using a Farmer chamber with lead filtering, (b) using a Farmer chamber without lead filtering, and (c) using a PinPoint chamber without lead filtering. Values of kQ were determined to be 0.995, 0.996, and 0.996 by each measurement technique, respectively. Halcyon™'s 6 MV-FFF beam was found to be broader than other FFF beams produced by Varian accelerators, and profile measurements at dmax showed the beam to vary less than 0.5% over the dimensions of our Farmer chamber's active volume. Reference dosimetry can be performed for the Halcyon™ accelerator simply, without specialized equipment or lead filtering with minimal dosimetric impact. This simplicity will prove advantageous in clinics with limited resources or physics support.


Assuntos
Radiometria , Aceleradores de Partículas , Fenilpropionatos , Fótons
13.
J Contemp Brachytherapy ; 8(3): 235-42, 2016 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-27504133

RESUMO

PURPOSE: Computed tomography (CT)-based prostate post-implant dosimetry allows for definitive seed localization but is associated with high interobserver variation in prostate contouring. Currently, magnetic resonance imaging (MRI)-based post-implant dosimetry allows for accurate anatomical delineation but is limited due to inconsistent seed localization. Encapsulated contrast agent markers were previously proposed to overcome the seed localization limitation on MRI images by placing hyperintense markers adjacent to hypointense seeds. The aim of this study was to assess the appearance of these markers in prostatic tissue, and develop an MRI protocol to enable marker visualization. MATERIAL AND METHODS: We acquired MRI scans in prostate implant patients (n = 10) on day 0 (day of implant) and day 30 (month after implant). Before implantation of the markers, the routine post-implant MRI protocol included a 3D T2-weighted fast-spin-echo (FSE) sequence with which markers and seeds could not be clearly visualized. To visualize the MRI markers, a 3D fast radiofrequency-spoiled gradient-recalled echo (FSPGR) sequence was evaluated for marker and seed visibility, as well as prostate boundary definitions. RESULTS: The 3D FSPGR sequence allowed for the visualization of markers in the prostate, enabling the distinction of signal voids as seeds versus needle tracks. The updated post-implant MRI protocol consists of this 3D FSPGR scan and an optional 3D T2-weighted FSE scan. The optional 3D T2-weighted FSE sequence may be employed to better visualize intraprostatic detail. We also described the observed image artifacts, including seed susceptibility, marker chemical shift, partial volume averaging, motion, and wraparound artifacts. CONCLUSIONS: We have demonstrated an MRI protocol for use with hyperintense encapsulated contrast agent markers to assist in the identification of hypointense seeds.

14.
Med Phys ; 43(7): 4312, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27370146

RESUMO

PURPOSE: For postimplant dosimetric assessment, computed tomography (CT) is commonly used to identify prostate brachytherapy seeds, at the expense of accurate anatomical contouring. Magnetic resonance imaging (MRI) is superior to CT for anatomical delineation, but identification of the negative-contrast seeds is challenging. Positive-contrast MRI markers were proposed to replace spacers to assist seed localization on MRI images. Visualization of these markers under varying scan parameters was investigated. METHODS: To simulate a clinical scenario, a prostate phantom was implanted with 66 markers and 86 seeds, and imaged on a 3.0T MRI scanner using a 3D fast radiofrequency-spoiled gradient recalled echo acquisition with various combinations of scan parameters. Scan parameters, including flip angle, number of excitations, bandwidth, field-of-view, slice thickness, and encoding steps were systematically varied to study their effects on signal, noise, scan time, image resolution, and artifacts. RESULTS: The effects of pulse sequence parameter selection on the marker signal strength and image noise were characterized. The authors also examined the tradeoff between signal-to-noise ratio, scan time, and image artifacts, such as the wraparound artifact, susceptibility artifact, chemical shift artifact, and partial volume averaging artifact. Given reasonable scan time and managable artifacts, the authors recommended scan parameter combinations that can provide robust visualization of the MRI markers. CONCLUSIONS: The recommended MRI pulse sequence protocol allows for consistent visualization of the markers to assist seed localization, potentially enabling MRI-only prostate postimplant dosimetry.


Assuntos
Braquiterapia/instrumentação , Braquiterapia/métodos , Marcadores Fiduciais , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Próstata/diagnóstico por imagem , Artefatos , Simulação por Computador , Humanos , Imageamento Tridimensional , Masculino , Imagens de Fantasmas , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Radiometria/instrumentação , Radiometria/métodos
15.
Phys Med Biol ; 59(10): 2505-16, 2014 May 21.
Artigo em Inglês | MEDLINE | ID: mdl-24778352

RESUMO

Brachytherapy, a radiotherapy technique for treating prostate cancer, involves the implantation of numerous radioactive seeds into the prostate. While the implanted seeds can be easily identified on a computed tomography image, distinguishing the prostate and surrounding soft tissues is not as straightforward. Magnetic resonance imaging (MRI) offers superior anatomical delineation, but the seeds appear as dark voids and are difficult to identify, thus creating a conundrum. Cobalt dichloride-N-acetyl-cysteine (C4) has previously been shown to be promising as an encapsulated contrast agent marker. We performed spin-lattice relaxation time (T1) and spin-spin relaxation time (T2) measurements of C4 solutions with varying cobalt dichloride concentrations to determine the corresponding relaxivities, r1 and r2. These relaxation parameters were investigated at different field strengths, temperatures and orientations. T1 measurements obtained at 1.5 and 3.0 T, as well as at room and body temperature, showed that r1 is field-independent and temperature-independent. Conversely, the T2 values at 3.0 T were shorter than at 1.5 T, while the T2 values at body temperature were slightly higher than at room temperature. By examining the relaxivities with the C4 vials aligned in three different planes, we found no orientation-dependence. With these relaxation characteristics, we aim to develop pulse sequences that will enhance the C4 signal against prostatic stroma. Ultimately, the use of C4 as a positive contrast agent marker will encourage the use of MRI to obtain an accurate representation of the radiation dose delivered to the prostate and surrounding normal anatomical structures.


Assuntos
Acetilcisteína , Braquiterapia/normas , Meios de Contraste , Marcadores Fiduciais , Imageamento por Ressonância Magnética , Neoplasias da Próstata/diagnóstico , Neoplasias da Próstata/radioterapia , Humanos , Masculino , Temperatura , Fatores de Tempo
16.
BMC Res Notes ; 5: 81, 2012 Jan 31.
Artigo em Inglês | MEDLINE | ID: mdl-22293603

RESUMO

BACKGROUND: Classifying the fungal and viral content of a sample is an important component of analyzing microbial communities in environmental media. Therefore, a method to classify any fragment from these organisms' DNA should be implemented. RESULTS: We update the näive Bayes classification (NBC) tool to classify reads originating from viral and fungal organisms. NBC classifies a fungal dataset similarly to Basic Local Alignment Search Tool (BLAST) and the Ribosomal Database Project (RDP) classifier. We also show NBC's similarities and differences to RDP on a fungal large subunit (LSU) ribosomal DNA dataset. For viruses in the training database, strain classification accuracy is 98%, while for those reads originating from sequences not in the database, the order-level accuracy is 78%, where order indicates the taxonomic level in the tree of life. CONCLUSIONS: In addition to being competitive to other classifiers available, NBC has the potential to handle reads originating from any location in the genome. We recommend using the Bacteria/Archaea, Fungal, and Virus databases separately due to algorithmic biases towards long genomes. The tool is publicly available at: http://nbc.ece.drexel.edu.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...